Command Descriptions

 

 

 

 

 

GS ( k PDF417<Function 065>

 

 

VERSAJET MP3200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Programming Reference

[Format]

ASCII

GS ( k pL pH cn fn n

 

 

 

 

 

 

 

 

 

 

 

Hex

1D 28 6B 03 00 30 41 n

 

 

 

 

 

 

Decimal

29 40 107 3 00 48 65 n

 

 

 

 

 

[Range]

(pL + pH x 256) = 3 (pL =3, pH =0)

 

 

 

 

 

 

cn = 48, fn = 65

 

 

 

 

 

 

0 ” n ” 30

 

 

 

 

 

 

[Default]

n = 0

 

 

 

 

 

 

[Description]

Specifies the number of columns of the data area of PDF417.

 

 

 

 

 

 

‹ n = 0 specifies auto processing

 

 

 

 

 

 

‹ When n is not 0, specifies the number of columns of the data area as n code word.

[Notes]

‹Settings of this function affect the processing of Functions 081 and 082.

‹When auto processing (n = 0) is specified, the maximum number of columns in the data area is 30 columns.

‹The following data is not included in the number of columns:

„Start pattern and stop pattern.

„Indicator code word of left and right.

‹When auto processing (n = 0) is specified, the number of columns is calculated by the printing area when processing Functions 081.

‹Settings of this function are effective until ESC @ is executed, the printer is reset, or the power is turned off.

117

Preliminary Rev. 02

Page 123
Image 123
Cino MP3200 manual GS k pL pH cn fn n