Command Descriptions
|
|
|
|
| GS ( k | Datamatrix <Function 780> | |||
|
| VERSAJET MP3200 |
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Programming Reference | [Format] |
| ASCII | GS ( k pL pH cn fn m d1…dk | ||||
|
|
|
|
|
| ||||
|
|
|
|
|
|
| Hex | 1D 28 6B pL pH 37 50 30 d1…dk | |
|
|
|
|
|
|
| Decimal | 29 40 | 107 pL pH 55 80 48 d1…dk |
|
|
|
|
| [Range] |
| 4 ҏ(pL + pH x ҏ256) | ҏ65535 (0 pLҏ ҏ255, 0 pHҏ ҏ255) | |
|
|
|
|
|
|
| cn = 55 |
|
|
|
|
|
|
|
|
| fn = 80 |
|
|
m = 48
0 ҏd ҏ255
k = (pL + pH xҏ256) – 3
[Description] | Stores the Datamatrix symbol data ( d1...dk) in the symbol save area. |
[Notes]
Data stored in the symbol save area by this function are processed by Function 781. The data in the symbol save area are reserved after processing Function 781 .
k bytes of d1...dk are processed as symbol data.
Specify only the data code word of the symbol with this function. Be sure not to include the following data in the data d1...dk because they are added automatically by the printer.
Start pattern and stop pattern
ndicator code word of left and right
The descriptor of symbol length (the first code word in the data area)
The error correction code word calculated by modulus 929
Settings of this function are effective until the following processing is performed:
Function 080 or 180 or 280 or 780 or 880 or 980 is executed
ESC @ is executed
The printer is reset or the power is turned off
144 | Preliminary Rev. 02 |