Command Descriptions

‹ If the horizontal or vertical logical origin is set outside the printable area, this command is canceled, and the following data is processed as normal data.

‹ If [horizontal logical origin + printing area width] exceeds the printable area, the clearing area width is automatically set to [horizontal printable area – horizontal logical origin].

‹ If [vertical logical origin + printing area height] exceeds the printable area, the clearing area height is automatically set to [vertical printable area – vertical logical origin].

‹ The clearing area and the logical origin set by this command are effective only in page mode.

‹ This command setting has no effect in standard mode. If this command is processed in standard mode, the logical origin and the printing area are set, and they are enabled when the printer selects page mode.

‹ Horizontal logical origin and printing area width are calculated using the vertical motion unit.

‹ Vertical logical origin and printing area height are calculated using the horizontal motion unit.

‹ Even if the horizontal or vertical motion unit is changed the printable area, the setting of the clearing area will not be changed.

‹ The settings of this command are effective until FF is executed, ESC @ is executed, the printer is reset, or the power is turned off.