Command Descriptions
|
|
|
|
| GS ( K <Function 49> |
|
| |||
|
| VERSAJET MP3200 |
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Programming Reference | [Name] |
| Selects printing density | ||||||
|
|
|
|
|
| |||||
|
|
|
|
| [Format] |
| ASCII | GS ( K pL pH fn m | ||
|
|
|
|
|
|
| Hex | 1D 28 4B 02 00 31 m | ||
|
|
|
|
|
|
| Decimal | 29 40 75 2 0 49 m | ||
|
|
|
|
| [Range] |
| (pL + pH x 256) = 2 (pL = 2, pH = 0) | |||
|
|
|
|
|
|
| fn = 49, 0 m 15 | |||
|
|
|
|
| [Default] |
| m = 8 |
|
| |
|
|
|
|
| [Description] |
| Selects printing control mode by m. | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| m |
| Function |
|
|
|
|
|
|
|
| m < 8 | Selects pale density |
| |
|
|
|
|
|
|
| m = 8 | Selects standard density |
| |
|
|
|
|
|
|
| m > 8 | Selects strong density |
|
The specification of each printing control mode differs, depending on the printer model. See
[Notes]
When a standard mode is selected, all the data in a line is printed in the same density.
When a page mode is selected, all the data printed collectively by FF or ESC FF is printed in the same density.
105 | Preliminary Rev. 02 |