Command Descriptions
|
|
|
|
| RS W |
|
|
|
| VERSAJET MP3200 |
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Programming Reference | [Name] | Clear printable area in page mode | ||||
|
|
|
|
| |||
|
|
|
|
| [Format] | ASCII | RS W xL xH yL yH dxL dxH dyL dyH |
|
|
|
|
|
| Hex | 1E 57 xL xH yL yH dxL dxH dyL dyH |
|
|
|
|
|
| Decimal | 30 87 xL xH yL yH dxL dxH dyL dyH |
|
|
|
|
| [Range] | 0 xL, xH, yL, yH, dxL, dxH, dyL, dyH 255 | |
|
|
|
|
|
| (except for dxL = dxH = 0 or dyL = dyH = 0) | |
|
|
|
|
| [Default] | Horizontal logical origin and vertical logical origin = 0 | |
|
|
|
|
|
| xL=0, xH=0, yL=0, yH=0 | |
|
|
|
|
|
| dxL = 0, dxH = 2, dyL = 126, dyH = 6 | |
|
|
|
|
| [Description] | In page mode, clears the size and the logical origin of the printing area as follows: | |
|
|
|
|
|
| Horizontal logical origin = (xL + xH x256) x (horizontal motion unit) from absolute origin. | |
|
|
|
|
|
| Vertical logical origin = (yL + yH x256) x (vertical motion unit) from absolute origin. |
Clearing area width = (dxL + dxH x256) x (horizontal motion unit). Clearing area height = (dyL + dyH x256) x (vertical motion unit).
[Notes]
This command must be used with “RS s”.
Both clearing area width and height cannot be set to 0.
The absolute origin is the upper left of the printable area.
99 | Preliminary Rev. 02 |