Command Descriptions
|
|
|
|
| GS ( k PDF417<Function 068> | ||
|
| VERSAJET MP3200 |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Programming Reference | [Format] | ASCII | GS ( k pL pH cn fn n | |||
|
|
|
|
| |||
|
|
|
|
|
| Hex | 1D 28 6B 03 00 30 44 n |
|
|
|
|
|
| Decimal | 29 40 107 03 00 48 68 n |
|
|
|
|
| [Range] | (pL + pH x256) = 3 (pL=3,pH =0) | |
|
|
|
|
|
| cn = 48, fn = 68, 5 n 100 | |
|
|
|
|
| [Default] | n = 5 |
|
|
|
|
|
| [Description] | Specifies the height of a module of PDF417 symbol. |
[Notes]
Settings of this function affect the processing of Functions 081.
Settings of this function are effective until ESC @ is executed, the printer is reset, or the power is turned off.
The module height influences the recognition rate of the symbol.
The setting unit is 0.1 mm.
120 | Preliminary Rev. 02 |