Command Descriptions

 

 

 

 

 

GS ( k PDF417<Function 068>

 

 

VERSAJET MP3200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Programming Reference

[Format]

ASCII

GS ( k pL pH cn fn n

 

 

 

 

 

 

 

 

 

 

 

Hex

1D 28 6B 03 00 30 44 n

 

 

 

 

 

 

Decimal

29 40 107 03 00 48 68 n

 

 

 

 

 

[Range]

(pL + pH x256) = 3 (pL=3,pH =0)

 

 

 

 

 

 

cn = 48, fn = 68, 5 ” n ”100

 

 

 

 

 

[Default]

n = 5

 

 

 

 

 

 

[Description]

Specifies the height of a module of PDF417 symbol.

[Notes]

‹Settings of this function affect the processing of Functions 081.

‹Settings of this function are effective until ESC @ is executed, the printer is reset, or the power is turned off.

‹The module height influences the recognition rate of the symbol.

‹The setting unit is 0.1 mm.