Cisco Systems 78-16845-01 manual GNE trap port GNE community string public GNE version

Models: 78-16845-01

1 68
Download 68 pages 52.71 Kb
Page 9
Image 9
GNE trap port: 162

Chapter 3 Building the Network

3.5.1 Prerequisites for Adding NEs

Note To add an ONS 15302 or ONS 15305 NE to CTM, its SNMP Users table must contain the following row:

0.0.0.0public true where, public is the community string. In addition, to obtain the trap events from the NE, the CTM Server IP address must be added to the NE. Refer to the Cisco Edge Craft User Documentation for more information.

3.5.1.3Prerequisites for Adding ONS 15310, ONS 15454 SONET, and ONS 15454 SDH NEs

Before adding ONS 15310, ONS 15454 SONET, or ONS 15454 SDH NEs with ML-series cards to CTM, make sure the NEs are properly set up according to the following:

A valid SNMP community string must be given when adding an NE with ML-series cards to resync Syslog and Configuration events. Audit log messages will be added in case of a resync failure.

A trap destination with IP address=CTM Server IP address, UDP Port=162, SNMP version=SNMPv2, maximum Traps/second=0, and SNMP community string must be created and must allow SNMP sets to receive traps from ML-series modules.

The Cisco IOS startup-config file must have the snmp-server enable traps command to receive traps from ML-series modules.

Whenever the user changes the trap destination for NE IP address and port=162 in either CTC or CTM, NEs must be out of service to resync the ML-series card events and be registered for traps. Change the operational state of the NE to In Service after making the changes.

If your network contains ML cards, note the following SNMP configuration requirements in a GNE/ENE scenario:

1.SNMPv1 uses the following configurations on GNEs and ENEs for traps: GNE trap destination: CTM server IP address

GNE trap port: 162

GNE community string: public

GNE version: v1

ENEs have two possible configurations: a. First configuration:

ENE trap destination: GNE IP address

ENE trap port: 391

ENE community string: Same as on GNE

ENE version: v1

b.Second configuration:

ENE trap destination: CTM server IP address

Relay A IP address: IP address of the NE that is directly connected to the ENE

Relay A community string: Same as on all other NEs

Relay B IP address: IP address of the NE that is directly connected to the Relay A NE

Relay B community string: Same as on all other NEs

Relay C IP address: IP address of the NE that is directly connected to the Relay B NE

Relay C community string: Same as on all other NEs

Cisco Transport Manager Release 6.0 User Guide

 

78-16845-01

3-9

 

 

 

Page 9
Image 9
Cisco Systems 78-16845-01 manual GNE trap port GNE community string public GNE version