3-25
Cisco ASR 903 Router Hardware Installation Guide
OL-25178-05
Chapter3 Installing the Cisco ASR 903 Router
Installing the Power Supply
Caution Secure the wires coming in from the terminal block plug so that they cannot be disturbed by
casual contact.
Step7 Ensure that the terminal block plug is fully seated in the terminal block header on the DC power supply
panel. The plug has a locking feature. You should hear a snap or click when it is installed properly.
Step8 Use a tie wrap to secure the wires to the rack, so that the wires are not pulled from the terminal block
plug by casual contact. Make sure the tie wrap allows for some slack in the ground wire, as shown in
Figure 3-22.
Figure3-22 Complete DC Terminal Block Plug Insertion and Secure Tie Wrap
Step9 Use a tie wrap to secure the wires to the handle. Leave a service loop on the ground wire between the
handle and the connector such that it is the last to receive strain if the wires are pulled.
This completes the procedure for connecting the DC power supply in the CiscoASR 903 Router.
If you are installing a redundant DC power supply, repeat these steps for the second power source.
Installing Terminal Block Connector on the DC PEM Unit (A900-PWR550-D-E)

Tools

12 AW G to 1 6 AWG cab les
Lugs fork-type or ring-type (Burndy, see Table 6 -2)—TP10 -6 or TP10-8F (recommended)
1Lead wires secured with a tie wrap 2DC power supply terminal block plug being
inserted into terminal block header.
INPUT
OK
OUTPUT
FAIL
24V—60V 28A
INPUT
OK
OUTPUT
FAIL
24V—60V 28A
RUDY RSP
MEM TOD BITSMGMT
ENET
1PPS
IN
1PPS
OUT
1OMHZ
OUT
1OMHZ
IN
CONSOLE
SYNC
ACT
PWR
STAT
255731
ALARM
FAN TEMP
CRIT MAJ MIN
1
2