Chapter 3 Installing the Cisco ASR 903 Router
Connecting the Cisco ASR 903 Router to the Network
Figure 3-26 Cisco ASR 903 Router Flash Token Memory Stick
209390
Removing a USB Flash Device
To remove and then replace a USB flash token memory stick from a Cisco ASR 903 Router, follow these steps:
Step 1 Pull the memory stick from the USB port.
Step 2 To replace a Cisco USB Flash memory stick, simply insert the module into the USB port labeled MEM as shown in Figure
Note You can insert or remove the memory stick whether the router is powered on or not.
This completes the USB Flash memory installation procedure.
Connecting Timing Cables
The following sections describe how to connect timing cables to the Cisco ASR 903 Router:
•Connecting Cables to the BITS Interface, page
•Connecting Cables to a GPS Interface, page
Note When installing the cabling to the RSPs, we recommend that you leave a service loop of extra cabling sufficient to allow for fan tray removal.
Connecting Cables to the BITS Interface
The following steps describe how to connect a cable to the router BITS port:
Step 1 Confirm that the router is powered off.
Step 2 Connect one end of the cable to the BITS port using a
|
| Cisco ASR 903 Router Hardware Installation Guide |
|
| |
|
|
| |||
|
|
|
| ||
|
|
|
|