Chapter 3 Installing the Cisco ASR 903 Router

Installing the Power Supply

OUTPUT FAIL LED is green

Step 4 If the LEDs indicate a power problem, see the Chapter 5, “Troubleshooting”for troubleshooting information.

Step 5 If you are installing a redundant power supply, repeat these steps for the second power source.

Note If you are installing a redundant AC power supply, ensure that each power supply is connected to a separate power source in order to prevent power loss in the event of a power failure.

Removing and Replacing the AC Power Supply

 

 

 

 

 

 

This section describes how to remove and replace the AC power supply.

 

 

 

 

 

 

 

 

 

 

 

Note

The Cisco ASR 903 Router power supplies are hot-swappable. If you have installed redundant power

 

 

 

 

 

 

supply modules, you can replace a single power supply without interrupting power to the router.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Caution

To avoid erroneous failure messages, allow at least 2 minutes for the system to reinitialize after a power

 

 

 

 

 

 

supply has been removed or replaced.

 

 

 

 

 

 

 

 

 

 

 

Warning

When you install the unit, the ground connection must always be made first and disconnected last.

 

 

 

 

 

 

Statement 1046

 

 

 

 

 

 

 

 

 

Warning

Before performing any of the following procedures, ensure that power is removed from the DC circuit.

 

 

 

 

 

 

Statement 1003

 

 

 

 

 

 

 

 

 

Warning

Only trained and qualified personnel should be allowed to install, replace, or service this equipment.

 

 

 

 

 

 

Statement 1030

 

 

 

 

 

 

 

 

 

Warning

Installation of the equipment must comply with local and national electrical codes. Statement 1074

 

 

 

 

 

 

 

 

 

 

 

 

 

Follow these steps to remove and replace the AC power supply:

 

 

 

 

 

 

 

 

Step 1

Disconnect the power cord from the power source. Do not touch the metal prongs on the power cord

 

 

 

 

 

 

when it is still connected to the power supply.

 

 

 

Step 2

Remove the power cord from the power connection on the power supply. Do not touch the metal prongs

 

 

 

 

 

 

embedded in the power supply.

 

 

 

Step 3

Loosen the captive installation screws.

 

 

 

Step 4

Grasp the AC power supply with one hand, and slide it part of the way out of the chassis. Place your

 

 

 

 

 

 

other hand underneath the power supply, and slide it completely out of the chassis.

 

 

 

 

 

 

Cisco ASR 903 Router Hardware Installation Guide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OL-25178-05

 

 

3-29

 

 

 

 

 

Page 85
Image 85