ASIC Driver Commands on Cisco IOS XR Software

clear controller ingressq statistics

clear controller ingressq statistics

To clear application-specific integrated circuit (ASIC) statics from the ingress fabric queue on a specific node, or on all nodes installed in the router, use the clear controller ingressq statistics command in EXEC mode.

clear controller ingressq statistics location node-id

Syntax Description

location node-id

Identifies the node whose ASIC statistics you want to clear from the ingress

 

 

fabric queue. The node-idargument is entered in the rack/slot/module

 

 

notation.

 

 

 

Defaults

Command Modes

Command History

Enter the clear controller ingressq statistics command without the optional location node-idkeyword argument to clear the ASIC statistics from the ingress queues on all nodes that are installed in the router.

EXEC

Release

Modification

Release 2.0

This command was introduced on the Cisco CRS-1.

 

 

Release 3.0

No modification.

 

 

Release 3.2

No modification.

 

 

Release 3.3.0

No modification.

 

 

Release 3.4.0

No modification.

 

 

Release 3.5.0

No modification.

 

 

Release 3.6.0

The location node-idkeyword and argument were changed from optional to

 

required.

 

 

Usage Guidelines To use this command, you must be in a user group associated with a task group that includes the proper task IDs. For detailed information about user groups and task IDs, see the Configuring AAA Services on Cisco IOS XR Software module of the Cisco IOS XR System Security Configuration Guide.

Only locations that contain a fabric queue ASIC can be specified for the location node-id.

The clear controller ingressq statistics command is intended for use while performing special maintenance, test, or debugging procedures. You do not need to use this command when fabric connectivity is performing normally.