The common problems you will see with the mold are that it will not close or it will not open. You need to check settings and electrical connections.

THE MOLD IS

NOT WORKING

PROPERLY

Symptom Possible cause Solution

The mold does not close.

The mold does not open.

The arm is not in the full Check the Arm Up (LS-3) and

up position, or at the Swing Outward End (LS-1)

swing outward end. switches and adjust as needed.

The safety interlock is on. Check the output and wiring.

The part verification sig- Check that the part verification

nal is not working. is on. Replace the switch if necessary.

The optional cycle start

Check the output and wiring.

signal is not working.

 

 

 

The arm is not in the full Check the Arm Up (LS-3) and

up position, or at the Swing Outward End (LS-1)

swing outward end. switches and adjust as needed.

The safety interlock is on. Check the output and wiring.

UGR003/0900

UCR-150L Robot

TROUBLESHOOTING 6-5

Page 57
Image 57
Conair UGR003/0800 manual Mold is Not Working Properly, Safety interlock is on. Check the output and wiring