THE ARM IS

NOT WORKING

PROPERLY

The problems you will see with the arm is that it will not extend or retract properly. Check electrical wiring, switches, valves, and air lines.

Symptom

Possible cause

Solution

 

There is no arm

There is no air pressure.

Check air supply to the robot.

 

extension (no arm

 

Check for leaks.

 

down).

 

 

 

 

The mold is not fully

Check that the interface wiring

 

 

open.

is correct.

 

 

 

 

 

 

The robot is not swung

Check the LS-1 and LS-2

 

 

fully in or fully out.

switches and adjust as neces-

 

 

 

sary.

 

 

 

 

 

 

Vertical stroke adjust-

Loosen stroke adjustment

 

 

ment block is set too low.

block and set higher to correct

 

 

 

stroke.

 

 

 

 

 

 

The arm down flow con-

Adjust the down speed control;

 

 

trol is shut off.

replace as needed.

 

 

 

 

 

 

The main arm solenoid

Replace the main arm solenoid

 

 

valve is not functioning.

valve.

 

 

 

 

 

 

The air lines/seals are

Check air lines and seals;

 

 

damaged or leaking.

replace as needed.

 

 

 

 

 

There is no arm

There is no air pressure.

Check air supply to the robot.

 

retraction (no arm

 

 

 

up).

 

 

 

 

 

 

The up solenoid is not functioning.

Replace the up solenoid valve.