Conair UGR003/0800 manual There is no vac Air pressure is incor Uum Rect

Models: UGR003/0800

1 100
Download 100 pages 47.05 Kb
Page 62
Image 62

THERE IS NO

When the vacuum is not working, check settings, air line problems, and bad solenoids.

VACUUM

Symptom

Possible cause Solution

There is no vac-

The air pressure is incor-

uum.

rect.

Check the air pressure. Adjust as needed.

The mode setting is incor- Set the mode for vacuum. rect.

The vacuum solenoid is Replace the vacuum solenoid. not working properly.

The air lines/seals are

Check the air lines and seals

damaged or leaking.

and replace as needed.

 

 

The part/sprue is sticking

Adjust the ejector stroke.

to the mold.

Correct the mold problem.

6-10