D-Link DES-3250TG Standalone Layer 2 Switch

Figure 9- 10. Rx Error Analysis window (table)

The following fields can be set:

 

Parameter

Description

 

Time Interval [1s ]

Select the desired setting between 1s and 60s,

 

 

where “s” stands for seconds. The default

 

 

value is one second.

 

Record Number [200]

Select number of times the Switch will be

 

 

polled between 20 and 200. The default value

 

 

is 20.

 

CrcError

Counts otherwise valid frames that did not

 

 

end on a byte (octet) boundary.

 

UnderSize

The number of frames detected that are less

 

 

than the minimum permitted frame size of 64

 

 

bytes and have a good CRC. Undersize

 

 

frames usually indicate collision fragments, a

 

 

normal network occurrence.

 

OverSize

Counts packets received that were longer

 

 

than 1518 octets, or if a VLAN frame 1522

 

 

octets, and less than the MAX_PKT_LEN.

 

 

Internally, MAX_PKT_LEN is equal to

 

 

1522.

 

 

Fragment

The number of packets less than 64 bytes

 

 

with either bad framing or an invalid CRC.

 

 

These are normally the result of collisions.

 

 

 

 

132

Page 142
Image 142
D-Link DES-3250TG manual CrcError, UnderSize, OverSize, Fragment, 132