DXS/DWS 3200 Series User Guide

TRAP — Indicates that an SNMP trap is generated, and sent via the Trap mechanism. The Trap can also be saved using the Trap mechanism.

Both— Indicates that both the Log and Trap mechanism are used to report alarms.

Falling Threshold — Displays the falling counter value that triggers the falling threshold alarm. The falling threshold is graphically presented on top of the graph bars. Each monitored variable is designated a color.

Falling Event — Displays the mechanism in which the alarms are reported.

Startup Alarm — Displays the trigger that activates the alarm generation. Rising is defined by crossing the threshold from a low-value threshold to a higher-value threshold.

Interval — Defines the alarm interval time in seconds.

Owner — Displays the device or user that defined the alarm.

Remove — Removes the RMON Alarms Table entry.

2.Click . The Add Alarms Entry Page opens:

Figure 208:Add Alarms Entry Page

3.Define the Interface, Counter Name, Sample Type, Rising Threshold, Rising Event, Falling Threshold, Falling Event, Startup Alarm, Interval, and Owner fields.

4.Click . The RMON alarm is added, and the device is updated.