Viewing Statistics

Managing RMON Statistics

Defining RMON Alarms

The RMON Alarm Page contains fields for setting network alarms. Network alarms occur when a network problem, or event, is detected. Rising and falling thresholds generate events. To set RMON alarms:

1.Click Advanced Setup > RMON > Alarm. The RMON Alarm Page opens.

Figure 207:RMON Alarm Page

The RMON Alarm Page contains the following fields:

Alarm Entry — Indicates a specific alarm.

Counter Name — Displays the selected MIB variable.

Interface — Displays interface for which RMON statistics are displayed. The possible field values are:

Port — Displays the RMON statistics for the selected port.

LAG — Displays the RMON statistics for the selected LAG.

Counter Value — Displays the selected MIB variable value.

Sample Type — Defines the sampling method for the selected variable and comparing the value against the thresholds. The possible field values are:

Delta — Subtracts the last sampled value from the current value. The difference in the values is compared to the threshold.

Absolute — Compares the values directly with the thresholds at the end of the sampling interval.

Rising Threshold — Displays the rising counter value that triggers the rising threshold alarm. The rising threshold is presented on top of the graph bars. Each monitored variable is designated a color.

Rising Event — Displays the mechanism in which the alarms are reported. The possible field values are:

LOG — Indicates there is not a saving mechanism for either the device or in the management system. If the device is not reset, the entry remains in the Log Table.

Page 315

Page 316
Image 316
D-Link DWS/DXS-3200 manual Defining Rmon Alarms, Click Advanced Setup Rmon Alarm. The Rmon Alarm Page opens