Table 6-3. Manage Volume Field Descriptions (continued)
Field | Description |
|
|
Consistency | This option is used to run a consistency check on a |
Check | redundant RAID volume. |
| This option is grayed out under the following conditions: |
| • The volume is RAID 0 |
| • The volume is not optimal |
| • The volume has a consistency check pending |
| • The volume is already running a consistency check |
|
|
Activate | This option is used to activate an inactive (foreign) volume. The option |
Volume | is grayed out if there are no inactive arrays. |
|
|
Delete | This option is used to delete the currently displayed volume. |
Volume |
|
|
|
Exit Screen
It is important to exit the SAS BIOS Configuration Utility properly, because some changes take effect only when you exit. From the Adapter List, press <Esc> to exit. In addition, a similar exit screen appears when you exit most other screens, and it can be used to save settings.
Performing Configuration Tasks
The following configuration tasks can be performed using a PERC H200 card:
•Creating a RAID 0, RAID 1, or RAID 10 virtual disk
•Viewing virtual disk properties
•Activating a virtual disk
•Migrating and Activating a virtual disk
•Hot Spare failover
•Replacing and Rebuilding a degraded virtual disk
•Assigning a Preferred Boot Device
PERC H200 and 6Gbps SAS HBA BIOS
51