Troubleshooting 65
BIOS Error Messages
Table 7-4. BIOS Error Messages
Message Meaning
Press <Ctrl+C> to
Enable BIOS
When the BIOS is disabled, you are given the option
to enable it by entering the Configuration Utility.
You can change the setting to Enabled in the
configuration utility.
Adapter configuration
may have changed,
reconfiguration is
recommended!
Press CTRL-C to run
Dell PERC H200/6Gbps
SAS HBA Configuration
Utility…
Start the Configuration Utility and confirm the
configuration of the PERC H200 or 6Gbps SAS HBA
controller.
Initializing... Displays while the BIOS is waiting to initialize.
SAS discovery error Indicates that there was a discovery error reported by
the firmware and may be accompanied by more such
messages. Enter the Configuration Utility to
investigate.
Integrated RAID
exception detected:
The BIOS detected an exception with one or more
RAID virtual disk. For additional troubleshooting
information, see the error message "Volume
(xx:yy:zzz) is currently in state
“STATE”.
PERC H200.book Page 65 Tuesday, July 13, 2010 4:15 PM