BIOS Error Messages
Table 7-4. BIOS Error Messages
Message | Meaning |
|
|
Press <Ctrl+C> to | When the BIOS is disabled, you are given the option |
Enable BIOS | to enable it by entering the Configuration Utility. |
| You can change the setting to Enabled in the |
| configuration utility. |
|
|
Adapter configuration | Start the Configuration Utility and confirm the |
may have changed, | configuration of the PERC H200 or 6Gbps SAS HBA |
reconfiguration is | controller. |
recommended! |
|
Press |
|
Dell PERC H200/6Gbps |
|
SAS HBA Configuration |
|
Utility… |
|
|
|
Initializing... | Displays while the BIOS is waiting to initialize. |
|
|
SAS discovery error | Indicates that there was a discovery error reported by |
| the firmware and may be accompanied by more such |
| messages. Enter the Configuration Utility to |
| investigate. |
|
|
Integrated RAID | The BIOS detected an exception with one or more |
exception detected: | RAID virtual disk. For additional troubleshooting |
| information, see the error message "Volume |
| (xx:yy:zzz) is currently in state |
| “STATE”. |
Troubleshooting
65