GAS SUPPLY:
■The connection must be performed by an authorised person according to the rele- vant standards.
■Before connecting the appliance to the gas main, mount the brass conical adaptor onto the gas inlet pipe, upon which the gasket has been placed (figures 1.10a- 1.10b).
Conical adaptor and gasket are supplied with the appliance (packed with conver- sion kit for use with Natural gas or Propane gas).
■This appliance is suitable for use with Natural Gas or Propane gas. (Check the “gas type” sticker attached to the appliance).
■For Natural Gas models the gas supply is connected to the pressure regulator which is supplied with the appliance (fig. 1.10b). Adjust the regulator to obtain a test point pressure of 1 kPa with one of the wok burners operating at the maxi- mum.
■For Propane gas models the gas supply is connected to the test point adaptor which is supplied with the appliance (fig. 1.10a) and ensure that the supply pres- sure is regulated to 2.75 kPa.
■The connection must be made at the rear of appliance. If the connection pipe cross the cooker, it must be positioned under the cooker rear protection (fig. 1.12).
■IMPORTANT: Use two spanners to tighten or loosen the connecting pipe (fig. 1.11)
Figure 1.10a
Gas connection for
PROPANE GAS
Gas inlet pipe
Nipple
Gasket
Brass conical adaptor
(Thread tight: use suitable seal)
Test point adaptor
Test point
Figure 1.10b
Gas connection for
NATURAL GAS
| Gas inlet pipe |
| Nipple |
| Gasket |
Test | Brass conical adaptor |
point | (Thread tight: use |
| suitable seal) |
Gas regulator
12