EverFocus EKR-KB1 operating instructions Elmo Dome, Setup

Models: EKR-KB1

1 236
Download 236 pages 39.44 Kb
Page 72
Image 72

6.6 Elmo Dome

6.6.1 Reference material and documents

Dome D7720B-J1P

Surveillance Control Protocol (DSCP), ver2.4, 2001.05.25

6.6.2 Connection

6.6.2.1 Cable

White

RS485A

Red

Yellow

RS485B

Black

Red

GND

Green

Warning!

Both phone-cables (one connected to the keyboard, the other to the dome) are supplied as standard with the EKR-KB1 keyboard. DO NOT USE the grey phone cable included in the ELMO dome equipment; its use can cause the damage of the keyboard.

6.6.2.2 Dome settings

Dome ID-number must be set according to the respective installation manual.

6.6.2.3 Keyboard settings

During Keyboard setup, submenu , must be suitably set:









Baudrate is fixed (9600 baud).

6.6.3 Setup

Dome setup is mostly carried out by On Screen Menu.

Some parameters can be set up by pressing a combination of keys or by inserting a special code.

For all setup operations the keyboard must be enabled to perform the receiver setup (menu ).