6.9 Ernitec Saturn Dome

6.9.1 Reference material and documents

Dome Ernitec Saturn

ICU Installation Instruction, Manual No.3040-00014, Rev.980220

6.9.2 Connection

6.9.2.1 Cable

White RS485A Rx+

Yellow RS485B Rx-

6.9.2.2 Dome settings

Dome ID-number must be set according to the respective installation manual.

Baudrate can be selected among the following values: 1200, 2400 (default), 4800, 9600, 19200 baud.

6.9.2.3 Keyboard settings

During Keyboard setup, submenu  must be suitably set:









Baudrate must be equal to the one selected for the dome.

6.9.3 Setup

Dome setup is mostly carried out by On Screen Menu.

Some parameters can be set up by pressing a combination of keys or by inserting a special code.

For all setup operations the keyboard must be enabled to perform the receiver setup (menu

