Resolving the DRAM Memory Error

Symptom: An error has occurred in the removable memory Module (SIMM). (Note: The

LCD will state the following: Main Memory Error.)

Step

Procedure

1

2

3

4

Reboot the Printer.

If the problem persists, remove the rear cover and ensure that the SIMM (080229) is seated properly.

If the memory Module is not seated properly, lock the SIMM into place.

If the installation appears correct and the error persists, the SIMM (080229) on the Main Print Board will need to be replaced.

Resolving the RAM Memory Error

Symptom: An error has occurred in the permanent circuit memory.

Step

Procedure

1

2

3

Reboot the Printer.

If the problem persists, replace the Main Print Board.

As an alternative to replacing the Main Print Board, the chip U22 may be replaced. (Note: Fargo recommends that only a qualified electronics technician perform this procedure.)

HDP600 High Definition Card Printer/Encoder User Guide (Rev. 2.3)