External Control Commands
Other optional settings include:
Field | Setting |
|
|
Baud Rate | Either 4800 or 1200 |
|
|
Parity | Odd or Even |
|
|
Stop Bit | 2 |
|
|
Data Bit | 7 |
|
|
Be sure that the control device and Firefly’s COM port settings are the same.
For Laserdisc Video serial communications, “LDV” must be selected in the Command Mode under System Settings.”VCC” is set for factory default.
Error Codes
If Firefly acknowledges a command, the return from the player will be <R>. Anytime an invalid command or address argument is received, that command will be ignored and an error code will be returned. In the event that the command was global, again each channel will report back independently.
The following table describes the system error codes:
Code | Message | Meaning |
|
|
|
NAK | Communication | Command or address argument |
| Error | cannot be parsed - invalid syntax. |
|
|
|
E06 | Missing Argument | Necessary parameter is not |
|
| specified. |
|
|
|
E11 | Playlist not loaded | This error will occur any time a |
|
| player control command is |
|
| received while no playlist is loaded. |
|
|
|
E12 | Search Error | Search or stop marker address |
|
| cannot be found. |
|
|
|
142