4.13Calibration (Standard Color Condition Setup)
■Measurement
1.Align the calibration pattern with the arrow, then align it to the
2.Press the [ |
| ] key. | |
| |||
| |||
★ The message changes to "Warming up", and the Auto- | |||
| Calibrator prepares to measure density. | ||
★ | When preparations for density measurement by the | ||
| |||
| operation panel changes to "Measuring" and density | ||
| measurement begins. | ||
★ When measurement ends without problems, the | |||
| message on the operation panel changes to "Data | ||
| Receiving". | ||
★ | When communications are finished, the message | ||
| changes to "Computing", indicating that calibration |
calculation is now underway.
★ When calibration calculation ends without problems, the message changes to "Complete".
NOTE: ● If the calibration pattern is inserted in reverse or inclined, the message "MarginError" or "NG Retry from Mesure Density" is displayed. Press the [ESC] key and correctly reinsert the calibration pattern.
●If "MarginError" is displayed even when the calibration pattern is inserted correctly, the position of the pattern image may have deviated significantly. See "4.8
Setting up the Print Image Position" to return the setting for "Margin Control" to "0". Go back and create a new calibration pattern.
3.Press the [ON LINE] key to return the machine to the ON | |
LINE mode. | 63 |
|