Warmingup

Measure

Data Receiving

Computing

Complete

MarginError

NG Retry from Mesure Density

4.13Calibration (Standard Color Condition Setup)

Measurement

1.Align the calibration pattern with the arrow, then align it to the right-hand end of the Auto-Calibrator insertion inlet. Insert the calibration pattern so that it just touches the end of the inlet.

2.Press the [

 

] key.

 

 

The message changes to "Warming up", and the Auto-

 

Calibrator prepares to measure density.

When preparations for density measurement by the

 

auto-calibrator are complete, the message on the

 

operation panel changes to "Measuring" and density

 

measurement begins.

When measurement ends without problems, the

 

message on the operation panel changes to "Data

 

Receiving".

When communications are finished, the message

 

changes to "Computing", indicating that calibration

calculation is now underway.

When calibration calculation ends without problems, the message changes to "Complete".

NOTE: If the calibration pattern is inserted in reverse or inclined, the message "MarginError" or "NG Retry from Mesure Density" is displayed. Press the [ESC] key and correctly reinsert the calibration pattern.

If "MarginError" is displayed even when the calibration pattern is inserted correctly, the position of the pattern image may have deviated significantly. See "4.8

Setting up the Print Image Position" to return the setting for "Margin Control" to "0". Go back and create a new calibration pattern.

3.Press the [ON LINE] key to return the machine to the ON

LINE mode.