Screw
Manual Cutter
SelfCheck
Warning
Check Donor - Magazine
6.2 Jamming at Location "1"
If the leading end of the donor gets caught and the donor
magazine cannot be pulled out, do the following steps.
10.Loosen the screw securing the knob [J12], pull the manual cutter towards you, and cut off the donor.
11.Return the manual cutter to its original position, and then tighten the screw securing the knob [J12].
IMPORTANT:
Prior to doing Step 12, make sure to secure the knob with the screw. If the knob is left loose, it will cause the equip- ment to malfunction.
12.Pull out the donor magazine.
13.With the donor magazine pulled out, close the inner door, lock the lock lever, and then close the lower front door.
★[Self Check] will appear on the operation panel and the paper remaining in the machine will be discharged automatically into the donor insertion section.
★After about 15 seconds, the discharging operation will be completed. An alarm will sound, and the following message will appear: [Warning Check
14.Open the lower front door and the inner door and remove the remaining discharged paper.
If the remaining paper has been removed, do Step 18.
If no remaining paper was discharged into the donor insertion section, do Steps 15 to 17, and then Step 18.