Partitions
315mm
297mm
254mm
127mm
102mm
3.5 Receiver Magazine Replacement
3.Remove the core of the receiver magazine and adjust the partitions to the receiver being used. The size of the receiver must correspond to the donor as shown below.
Size of receiver | Corresponding donor size |
|
|
315 mm (Double Letter Wide,etc.) | 323mm |
|
|
279 mm (Double Letter and Letter) | 305mm |
|
|
254 mm (10 x 12 and 10 x 8) | 262mm |
|
|
127 mm (5R,etc.) | 135mm |
|
|
102 mm (4R,etc.) | 135mm |
NOTE: Use the proper combination of donor and receiver. Do not use combinations other than those above. If you do, the message "Warning Check Magazine Type" appears.
4.Take out the receiver magazine from the casing and inner bag. Take the roll of the new receiver and insert the plastic flanges into the
| 5.Pull out the leading edge of the receiver about 0.8 in. (2 |
0.8 in. | cm) and insert it into the receiver replacement magazine. |
(2 cm) | Then close the cover and lock both sides firmly. |
|
6.Specify the type of receiver being used with the dip switch on the receiver magazine.
1 2 3 OFF ON
| Type | 1 | 2 | 3 | 4 | |
Dip Switch |
|
|
|
|
| |
Standard thickness, glossy, SG | ↓ | ↑ | ↑ | ↑ | ||
| ||||||
|
|
|
|
|
| |
| Thin glossy, LG | ↑ | ↓ | ↑ | ↑ | |
|
|
|
|
|
| |
| Standard thickness, matte, SM | ↓ | ↑ | ↓ | ↑ | |
|
|
|
|
|
| |
| Thin matte, LM | ↑ | ↓ | ↓ | ↑ | |
|
|
|
|
|
|
3
OPERATING PROCDURES
33