Accessing the Management Interface

 

Troubleshooting and Tips

10.2 Accessing the Management Interface

You can access the management interface for the IBP from anywhere within the attached network using Telnet, a Web browser, or any SNMP-based network management software. If you are having trouble accessing the management interface, then refer to the troubleshooting information displayed in the following table.

Symptom

 

 

Action

 

 

Cannot connect to the

• Be sure you have configured the agent with a valid IP address,

IBP using Telnet, Web

subnet mask and default gateway.

browser,

or

SNMP

• If you are trying to connect to the agent via the IP address for a

software

 

 

 

 

tagged VLAN group, your management station must include the

 

 

 

 

 

 

appropriate tag in its transmitted frames.

 

 

 

• Check that you have a valid network connection to the IBP

 

 

 

and that the port you are using has not been disabled.

 

 

 

• Check network cabling between the management station and the

 

 

 

IBP.

 

 

 

• If you cannot connect using Telnet, there may already be four

 

 

 

active sessions. Try connecting again at a later time.

 

 

 

Cannot access

the

• Be sure you have set the terminal emulator program to VT100

on-board

 

 

compatible, 8 data bits, 1 stop bit, no parity, and 19200 bps.

configuration program

• Check that the null-modem serial cable conforms to the pin-out

via a

serial

port

connections provided in the Operating Manual for the server.

connection

 

 

 

Forgot or

lost

the

• Restore the “Factory_Default_Config.cfg” file with the “boot

password

 

 

system” command described on page 134.

 

 

 

 

287

Intelligent Blade Panel Module

Page 288
Image 288
Fujitsu BX600 manual Accessing the Management Interface, Symptom Action