Panel Settings Menu
6.2.2.1.3Configuring Inband Administration Page
The network interface is the logical interface used for
To access the IBP module over a network you must first configure it with IP information (IP address, subnet mask, and default gateway). You can configure the IP information using any of the following:
BOOTP
DHCP
Terminal interface via the EIA-232 port
Once you have established
Terminal interface via the
Terminal interface via telnet
Configurable Data
IP Address - The IP address of the interface. The factory default value is 0.0.0.0 Subnet Mask - The IP subnet mask for the interface. The factory default value is 0.0.0.0
Default Gateway - The default gateway for the IP interface. The factory default value is 0.0.0.0
Network Configuration Protocol Current - Choose what the IBP module should do following
You cannot make this choice for both the network configuration protocol and the service port. You will only be given the choices for Bootp or DHCP here if the service port protocol is configured to None.
Inband Administration VLAN ID - Specifies the inband administration VLAN ID of the IBP module. It may be configured to any value in the range of 1 - 4094. The inband administration VLAN is used for management of the IBP module. This field is configurable for administrative users and
Web Mode - Specify whether the IBP may be accessed from a Web browser. If you choose to enable web mode you will be able to manage the IBP from a Web browser. The factory default is enabled.
Java Mode - Enable or disable the java applet that displays a picture of the IBP module at the top right of the screen. If you run the applet you will be able to click on the picture of the IBP to select configuration screens instead of using the navigation tree at the left side of the screen. The factory default is enabled.
Web Port - This field is used to set the HTTP Port Number. The value must be in the range of 1 to 65535. Port 80 is the default value. The currently configured value is shown when the web page is displayed.
Paticipation – This select field is used to set the interface to be grated or denied for