Panel Settings Menu
6.2.2.1.6Configuring Serial Port Page Configurable Data
Serial Port Login Timeout (minutes) - Specify how many minutes of inactivity should occur on a serial port connection before the IBP closes the connection. Enter a number between 0 and 160: the factory default is 5. Entering 0 disables the timeout.
Baud Rate (bps) - Select the default baud rate for the serial port connection from the
Password Threshold - When the logon attempt threshold is reached on the console port, the system interface becomes silent for a specified amount of time before allowing the next logon attempt. (Use the silent time command to set this interval.) When this threshold is reached for Telnet, the Telnet logon interface closes. The default value is 3.
Silent Time (Sec) - Use this command to set the amount of time the management console is inaccessible after the number of unsuccessful logon attempts exceeds the threshold set by the password threshold command. The default value is 0.
Non-Configurable Data
Character Size (bits) - The number of bits in a character. This is always 8.
Flow Control - Whether hardware flow control is enabled or disabled. It is always disabled.
Parity - The parity method used on the serial port. It is always None. Stop Bits - The number of stop bits per character. It is always 1.
Command Buttons
Submit - Update the IBP module with the values on the screen. If you want the IBP module to retain the new values across a power cycle you must perform a save.