Processors

Replacing the processor

6.2Replacing the processor

V CAUTION!

Only processors of the same type may be used on the system board. That means the number of the internal processor cores as well as the primary clock and the FSB frequency have to be the same. For dual operation, use a suitable multiprocessor operating system.

ÊOpen the server and remove the fan carrier as described in the chapter "Preparation" on page 27.

Removing the heat sink

￿

￿

￿

Figure 20: Removing the heat sink

ÊPress the heat sink retaining clips downward and inward.

ÊFold back the heat sink retaining clips (1).

ÊLoosen the heat sink by turning it back and forth and then lift it out (2).

ÊRemove the residual thermal paste from the underside of the heat sink.

ÊClean the underside of the heat sink using a lint-free cloth.