CHAPTER 7: ACCESS USING RADIUS

ACCESS USING RADIUS

Setting port control parameters (continued)

ML1200(auth)## backend port=2 supptimeout=45 servertimeout=60 maxreq=5

Successfully set backend server authentication parameter(s)

ML1200(auth)## show-port backend

Port Supp Timeout Server Timeout Max Request

(sec.)(sec.)

This command sets timeout characteristics and the number of requests before access is denied.

===============================================

 

The authenticator waits for the supplicant

1

30

30

2

to respond back for 45 seconds; the

2

45

60

5

authenticator waits for 60 seconds for the

3

30

30

2

back-end RADIUS server to respond back

4

30

30

2

and the authenticator will retransmit an

5

30

30

2

EAP request packet 5 times to the

6

30

30

2

ML1200(auth)## portaccess port=2 quiet=120 maxreauth=7

Supplicant before it times out the

transmit=120

Successfully set port access parameter(s)

authentication session.

 

 

ML1200(auth)## show-port access

 

Port

Quiet Period

Max Reauth

Tx Period

 

 

(sec.)

(sec.)

 

 

=========================================

 

1

60

2

30

 

2

120

7

120

 

3

60

2

30

 

4

60

2

30

 

5

60

2

30

 

6

60

2

30

 

(continued on following page)

The time the supplicant is held after an authentication failure before the authenticator retries the supplicant for connection is changed to 120 seconds, the number of re-authentication attempts permitted before the port becomes Unauthorized is set to 7, and the time the authenticator waits to transmit another request for identification from the supplicant is changed to 120 seconds. These values can be changed on all ports depending on devices being authenticated.

MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL

7–7

Page 131
Image 131
GE instruction manual Setting port control parameters, ML1200auth## show-port backend