CHAPTER 17: MISCELLANEOUS COMMANDS

MISCELLANEOUS COMMANDS

17.3Serial Connectivity

17.3.1 Description

When using the serial connectivity with applications such as HyperTerminal, it may be necessary to optimize the character delays so that the FIFO buffer used in the MultiLink ML1200 Managed Field Switch is not overrun. The important parameters to set for any serial connectivity software is to set the line delay to be 500 ms and the character delay to be 50 ms. For example, using HyperTerminal this can be set under File > Properties. When the Properties window is open, click on the ASCII Setup button and in the Line Delay entry box enter in 500 and in the Character Delay entry box enter in 50 as shown below.

754729A1.CDR

FIGURE 17–1: Optimizing serial connection in HyperTerminal

MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL

17–7

Page 277
Image 277
GE ML1200 instruction manual Serial Connectivity, Optimizing serial connection in HyperTerminal