GE instruction manual Power Budget Calculations for ML1200 PM’s with Fiber Media, Typical

Models: ML1200

1 344
Download 344 pages 51.98 Kb
Page 62
Image 62

OPERATION

CHAPTER 4: OPERATION

4.1.5Power Budget Calculations for ML1200 PM’s with Fiber Media

Receiver Sensitivity and Transmitter Power are the parameters necessary to compute the power budget. To calculate the power budget of different fiber media installations using Multilink products, the following equations should be used:

OPB (Optical Power Budget) = PT(min) - PR(min)

where PT = Transmitter Output Power, and PR = Receiver Sensitivity Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)

Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km] where the “Cable Loss” for 62.5/125 and 50/125μm (M.m) is 2.8 dB/km,

and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km,

and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km

and the “Cable Loss” for 9/125 (Single-mode) is 0.4 dB/km (LX25)

and the “Cable Loss” for 9/125 (Single-mode) is 0.25 dB/km (ZX40)

and the “Cable Loss” for 9/125 (Single-mode) is 0.2 dB/km (ZX70)

The following data has been collected from component manufacturer’s (Agilent’s and

Lucent’s) web sites and catalogs to provide guidance to network designers and installers.

Fiber Port

Speed, Std.

Mode

Std. km

Wavelength

Cable Size/μm

X’mitr

R’cvr

Worst

Worst*

 

typical

typical*

Module

 

 

fdx

nm

 

Output

Sens.

OPB,

distance

 

OPB,

distance

 

 

 

(hdx)

 

 

PT

PR

dB

Km

 

dB

Km

 

 

 

 

 

 

dB

dB

 

fdx

 

 

fdx

C7

10Mb

Multi-Mode

2

850

62.5/125

-15.0

-31

14

5

 

17

6

 

FL

 

(2)

 

100/140

-9.5

-31

19.5

5.9

 

23.5

7

 

 

 

 

 

50/125

-19.5

-31

19.5

3.4

 

13.5

4.8

 

 

 

 

 

 

 

 

 

 

 

 

 

C8, C9

100Mb

Multi-mode

2

1300

62.5/125

-20

-31

9.0

3.0

 

14

5

 

FX

 

(0.4)

 

50/125

-23.5

-31

5.5

2.0

 

12

4

 

 

 

 

 

 

 

 

 

 

 

 

 

CA

100Mb

Single-mode18+

1300

9/125

-15

-31

14

28

 

17.5

35

 

FX

 

(0.4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CB

100Mb

Single-mode40

1300

9/125

-5

-34

29

58

 

32.5

65

 

FX

 

(0.4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CC

100Mb

Multi-mode

2

1300

62.5/125

-20

-31

9.0

3.0

 

15.8

5.5

 

FX

 

(0.4)

 

50/125

-23.5

-31

5.5

2.0

 

12.2

4.0

 

 

 

 

 

 

 

 

 

 

 

 

 

CD

100Mb

Multi-mode

2

1300

62.5/125

-19

-31

12

4

 

16

5.7

 

FX

 

(0.4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CE

100Mb

Single-Mode 15+

1310

9/125

-15

-28

11

22

 

-

-

 

FX

 

(0.4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H3, HG

1000 Mb FX

Single-Mode 10

1310

9/125

-10.0

-22

10

22

 

11

24

 

(Gigabit)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4–4

MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL

Page 62
Image 62
GE instruction manual Power Budget Calculations for ML1200 PM’s with Fiber Media, Typical