ZOnce the file transfer is completed reboot the switch with the reboot command or by cycling power.

ZLogin to the switch and use the show version command to verify and upload the configuration file (if necessary).

1.6.4Updating through the EnerVista Secure Web Management software

Use the following procedure to install the EnerVista Secure Web Management software.

ZDownload the latest MultiLink ML1200 Managed Field Switch firmware from the GE Multilin web site.

ZSave this file on FTP or TFTP. Ensure the FTP or TFTP path is configured. If using FTP, record the FTP login name and password.

ZSelect the switch to upgrade. Ensure you have system administration privileges available on the switch.

ZOpen an EnerVista Secure Web Management software session with the switch by typing in the following URL:

https://<IP address of the switch>

If using FTP, save the configuration before proceeding. GE Multilin recommends a two-step update: first save the configuration to the ftp server, then load the new image and restart the switch (refer to section 5.4.4 - Saving Configuration for details on saving the configuration).

ZLoad the new firmware as shown below.

As the file is being loaded, the firmware will display the transfer in progress window.