GE ML1200 instruction manual Modbus memory map Sheet 18

Models: ML1200

1 344
Download 344 pages 51.98 Kb
Page 311
Image 311

CHAPTER 18: MODBUS PROTOCOL

MODBUS PROTOCOL

Table 18–1: Modbus memory map (Sheet 18 of 33)

Address

Description

Range

Step

Format

Default

 

 

 

 

 

 

03C8

Port 16: Number of frames received

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

03CA

Port 16: Number of frames sent

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

03CC

Port 16: Total bytes received

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

03CE

Port 16: Total frames received

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

03D0

Port 16: Number of broadcast frames

0 to

1

F9

0

 

received

4294967295

 

 

 

 

 

 

 

 

 

03D2

Port 16: Number of multicast frames

0 to

1

F9

0

 

received

4294967295

 

 

 

 

 

 

 

 

 

03D4

Port 16: Number of frames with CRC

0 to

1

F9

0

 

error

4294967295

 

 

 

 

 

 

 

 

 

03D6

Port 16: Number of oversized frames

0 to

1

F9

0

 

received

4294967295

 

 

 

 

 

 

 

 

 

03D8

Port 16: Number of bad fragments

0 to

1

F9

0

 

received (<64 bytes)

4294967295

 

 

 

 

 

 

 

 

 

03DA

Port 16: Number of jabber frames

0 to

1

F9

0

 

received

4294967295

 

 

 

 

 

 

 

 

 

03DC

Port 16: Number of collisions occurred

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

03DE

Port 16: Number of late collisions

0 to

1

F9

0

 

occurred

4294967295

 

 

 

 

 

 

 

 

 

03E0

Port 16: Number of 64-byte frames

0 to

1

F9

0

 

received/sent

4294967295

 

 

 

 

 

 

 

 

 

03E2

Port 16: Number of 65 to 127 byte

0 to

1

F9

0

 

frames received/sent

4294967295

 

 

 

 

 

 

 

 

 

03E4

Port 16: Number of 128 to 255 byte

0 to

1

F9

0

 

frames received/sent

4294967295

 

 

 

 

 

 

 

 

 

03E6

Port 16: Number of 256 to 511 byte

0 to

1

F9

0

 

frames received/sent

4294967295

 

 

 

 

 

 

 

 

 

03E8

Port 16: Number of 512 to 1023 byte

0 to

1

F9

0

 

frames received/sent

4294967295

 

 

 

 

 

 

 

 

 

03EA

Port 16: Number of 1023 to maximum

0 to

1

F9

0

 

byte frames received/sent

4294967295

 

 

 

 

 

 

 

 

 

03EC

Port 16: Number of MAC error packets

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

03EE

Port 16: Number of dropped received

0 to

1

F9

0

 

packets

4294967295

 

 

 

 

 

 

 

 

 

03F0

Port 16: Number of multicast frames

0 to

1

F9

0

 

sent

4294967295

 

 

 

 

 

 

 

 

 

03F2

Port 16: Number of broadcast frames

0 to

1

F9

0

 

sent

4294967295

 

 

 

 

 

 

 

 

 

03F4

Port 16: Number of <64 byte fragments

0 to

1

F9

0

 

with good CRC

4294967295

 

 

 

 

 

 

 

 

 

03F6

Port 17: Number of bytes received

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

03F8

Port 17: Number of bytes sent

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

03FA

Port 17: Number of frames received

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

03FC

Port 17: Number of frames sent

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

03FE

Port 17: Total bytes received

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL

18–21

Page 311
Image 311
GE ML1200 instruction manual Modbus memory map Sheet 18