Table 18–1: Modbus memory map (Sheet 26 of 33)

Address

Description

Range

Step

Format

Default

 

 

 

 

 

 

0588

Port 25: Number of bytes sent

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

058A

Port 25: Number of frames received

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

058C

Port 25: Number of frames sent

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

058E

Port 25: Total bytes received

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

0590

Port 25: Total frames received

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

0592

Port 25: Number of broadcast frames

0 to

1

F9

0

 

received

4294967295

 

 

 

 

 

 

 

 

 

0594

Port 25: Number of multicast frames

0 to

1

F9

0

 

received

4294967295

 

 

 

 

 

 

 

 

 

0596

Port 25: Number of frames with CRC

0 to

1

F9

0

 

error

4294967295

 

 

 

 

 

 

 

 

 

0598

Port 25: Number of oversized frames

0 to

1

F9

0

 

received

4294967295

 

 

 

 

 

 

 

 

 

059A

Port 25: Number of bad fragments

0 to

1

F9

0

 

received (<64 bytes)

4294967295

 

 

 

 

 

 

 

 

 

059C

Port 25: Number of jabber frames

0 to

1

F9

0

 

received

4294967295

 

 

 

 

 

 

 

 

 

059E

Port 25: Number of collisions occurred

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

05A0

Port 25: Number of late collisions

0 to

1

F9

0

 

occurred

4294967295

 

 

 

 

 

 

 

 

 

05A2

Port 25: Number of 64-byte frames

0 to

1

F9

0

 

received/sent

4294967295

 

 

 

 

 

 

 

 

 

05A4

Port 25: Number of 65 to 127 byte

0 to

1

F9

0

 

frames received/sent

4294967295

 

 

 

 

 

 

 

 

 

05A6

Port 25: Number of 128 to 255 byte

0 to

1

F9

0

 

frames received/sent

4294967295

 

 

 

 

 

 

 

 

 

05A8

Port 25: Number of 256 to 511 byte

0 to

1

F9

0

 

frames received/sent

4294967295

 

 

 

 

 

 

 

 

 

05AA

Port 25: Number of 512 to 1023 byte

0 to

1

F9

0

 

frames received/sent

4294967295

 

 

 

 

 

 

 

 

 

05AC

Port 25: Number of 1023 to maximum

0 to

1

F9

0

 

byte frames received/sent

4294967295

 

 

 

 

 

 

 

 

 

05AE

Port 25: Number of MAC error packets

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

05B0

Port 25: Number of dropped received

0 to

1

F9

0

 

packets

4294967295

 

 

 

 

 

 

 

 

 

05B2

Port 25: Number of multicast frames

0 to

1

F9

0

 

sent

4294967295

 

 

 

 

 

 

 

 

 

05B4

Port 25: Number of broadcast frames

0 to

1

F9

0

 

sent

4294967295

 

 

 

 

 

 

 

 

 

05B6

Port 25: Number of <64 byte fragments

0 to

1

F9

0

 

with good CRC

4294967295

 

 

 

 

 

 

 

 

 

05B8

Port 26: Number of bytes received

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

05BA

Port 26: Number of bytes sent

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

05BC

Port 26: Number of frames received

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

05BE

Port 26: Number of frames sent

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 