MODBUS PROTOCOL

CHAPTER 18: MODBUS PROTOCOL

18.2Memory Mapping

18.2.1 Modbus Memory Map

The Modbus memory map is shown below. Refer to Format Codes on page 18–37for details on the items in the format column.

Table 18–1: Modbus memory map (Sheet 1 of 33)

Address

Description

Range

Step

Format

Default

 

 

 

 

 

 

0000

System name (12 registers)

-

-

String

Varies

 

 

 

 

 

 

000C

System contact (12 registers)

-

-

String

multilin.tech

 

 

 

 

 

@ge.com

 

 

 

 

 

 

0018

System location (12 registers)

-

-

String

Markham, Ontario

 

 

 

 

 

 

0024

Software version (6 registers)

-

-

String

Varies

 

 

 

 

 

 

002A

IP address (byte 0)

1 to 254

1

F1

0

 

 

 

 

 

 

002B

IP address (byte 1)

1 to 254

1

F1

0

 

 

 

 

 

 

002C

IP address (byte 2)

1 to 254

1

F1

0

 

 

 

 

 

 

002D

IP address (byte 3)

1 to 254

1

F1

0

 

 

 

 

 

 

002E

Netmask (byte 0)

1 to 254

1

F1

0

 

 

 

 

 

 

002F

Netmask (byte 1)

1 to 254

1

F1

0

 

 

 

 

 

 

0030

Netmask (byte 2)

1 to 254

1

F1

0

 

 

 

 

 

 

0031

Netmask (byte 3)

1 to 254

1

F1

0

 

 

 

 

 

 

0032

Gateway (byte 0)

1 to 254

1

F1

0

 

 

 

 

 

 

0033

Gateway (byte 1)

1 to 254

1

F1

0

 

 

 

 

 

 

0034

Gateway (byte 2)

1 to 254

1

F1

0

 

 

 

 

 

 

0035

Gateway (byte 3)

1 to 254

1

F1

0

 

 

 

 

 

 

0036

MAC address (3 registers)

-

-

String

Varies

 

 

 

 

 

 

0039

Order code (16 registers)

-

-

String

Varies

 

 

 

 

 

 

0049

Power alarm 1

0 to 1

1

F2

0

 

 

 

 

 

 

004A

Power alarm 2

0 to 1

1

F2

0

 

 

 

 

 

 

004B

Stp State

0 to 1

1

F3

0

 

 

 

 

 

 

004C

Number of ports

1 to 32

1

F1

Varies

 

 

 

 

 

 

004E

Port present map

-

-

Bitmap

Varies

 

 

 

 

 

 

0050

Port link map

-

-

Bitmap

0

 

 

 

 

 

 

0052

Port stp state map

-

-

Bitmap

0

 

 

 

 

 

 

0054

Port activity map

-

-

Bitmap

0

 

 

 

 

 

 

0056

Port 1 type

0 to 6

1

F4

Varies

 

 

 

 

 

 

0057

Port 2 type

0 to 6

1

F4

Varies

 

 

 

 

 

 

0058

Port 3 type

0 to 6

1

F4

Varies

 

 

 

 

 

 

0059

Port 4 type

0 to 6

1

F4

Varies

 

 

 

 

 

 

005A

Port 5 type

0 to 6

1

F4

Varies

 

 

 

 

 

 

005B

Port 6 type

0 to 6

1

F4

Varies

 

 

 

 

 

 

005C

Port 7 type

0 to 6

1

F4

Varies

 

 

 

 

 

 

005D

Port 8 type

0 to 6

1

F4

Varies

 

 

 

 

 

 

005E

Port 9 type

0 to 6

1

F4

Varies

 

 

 

 

 

 

005F

Port 10 type

0 to 6

1

F4

Varies

 

 

 

 

 

 

0060

Port 11 type

0 to 6

1

F4

Varies

 

 

 

 

 

 

0061

Port 12 type

0 to 6

1

F4

Varies

 

 

 

 

 

 