GE ML1200 instruction manual Modbus memory map Sheet 19

Models: ML1200

1 344
Download 344 pages 51.98 Kb
Page 312
Image 312

MODBUS PROTOCOL

CHAPTER 18: MODBUS PROTOCOL

Table 18–1: Modbus memory map (Sheet 19 of 33)

Address

Description

Range

Step

Format

Default

 

 

 

 

 

 

0400

Port 17: Total frames received

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

0402

Port 17: Number of broadcast frames

0 to

1

F9

0

 

received

4294967295

 

 

 

 

 

 

 

 

 

0404

Port 17: Number of multicast frames

0 to

1

F9

0

 

received

4294967295

 

 

 

 

 

 

 

 

 

0406

Port 17: Number of frames with CRC

0 to

1

F9

0

 

error

4294967295

 

 

 

 

 

 

 

 

 

0408

Port 17: Number of oversized frames

0 to

1

F9

0

 

received

4294967295

 

 

 

 

 

 

 

 

 

040A

Port 17: Number of bad fragments

0 to

1

F9

0

 

received (<64 bytes)

4294967295

 

 

 

 

 

 

 

 

 

040C

Port 17: Number of jabber frames

0 to

1

F9

0

 

received

4294967295

 

 

 

 

 

 

 

 

 

040E

Port 17: Number of collisions occurred

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

0410

Port 17: Number of late collisions

0 to

1

F9

0

 

occurred

4294967295

 

 

 

 

 

 

 

 

 

0412

Port 17: Number of 64-byte frames

0 to

1

F9

0

 

received/sent

4294967295

 

 

 

 

 

 

 

 

 

0414

Port 17: Number of 65 to 127 byte

0 to

1

F9

0

 

frames received/sent

4294967295

 

 

 

 

 

 

 

 

 

0416

Port 17: Number of 128 to 255 byte

0 to

1

F9

0

 

frames received/sent

4294967295

 

 

 

 

 

 

 

 

 

0418

Port 17: Number of 256 to 511 byte

0 to

1

F9

0

 

frames received/sent

4294967295

 

 

 

 

 

 

 

 

 

041A

Port 17: Number of 512 to 1023 byte

0 to

1

F9

0

 

frames received/sent

4294967295

 

 

 

 

 

 

 

 

 

041C

Port 17: Number of 1023 to maximum

0 to

1

F9

0

 

byte frames received/sent

4294967295

 

 

 

 

 

 

 

 

 

041E

Port 17: Number of MAC error packets

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

0420

Port 17: Number of dropped received

0 to

1

F9

0

 

packets

4294967295

 

 

 

 

 

 

 

 

 

0422

Port 17: Number of multicast frames

0 to

1

F9

0

 

sent

4294967295

 

 

 

 

 

 

 

 

 

0424

Port 17: Number of broadcast frames

0 to

1

F9

0

 

sent

4294967295

 

 

 

 

 

 

 

 

 

0426

Port 17: Number of <64 byte fragments

0 to

1

F9

0

 

with good CRC

4294967295

 

 

 

 

 

 

 

 

 

0428

Port 18: Number of bytes received

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

042A

Port 18: Number of bytes sent

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

042C

Port 18: Number of frames received

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

042E

Port 18: Number of frames sent

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

0430

Port 18: Total bytes received

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

0432

Port 18: Total frames received

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

0434

Port 18: Number of broadcast frames

0 to

1

F9

0

 

received

4294967295

 

 

 

 

 

 

 

 

 

0436

Port 18: Number of multicast frames

0 to

1

F9

0

 

received

4294967295

 

 

 

 

 

 

 

 

 

18–22

MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL

Page 312