CHAPTER 7: ACCESS USING RADIUS

ACCESS USING RADIUS

The port authentication characteristics define how the authenticator (ML1200 switch) does the re-authentication with the supplicant or PC. These are defined through the Configuration > Radius > Port > Access > Reauth menu item.

The Reauth Period represents the time the authenticator waits before a re-authentication process will be done again to the supplicant. Values range from 10 to 86400 seconds, with a default of 3600 (1 hour).

The Configuration > Radius > Port > Stats menu item illustrates the radius statistics for each port.