MODBUS PROTOCOL

CHAPTER 18: MODBUS PROTOCOL

Table 18–1: Modbus memory map (Sheet 15 of 33)

Address

Description

Range

Step

Format

Default

 

 

 

 

 

 

0320

Port 12: Number of 512 to 1023 byte

0 to

1

F9

0

 

frames received/sent

4294967295

 

 

 

 

 

 

 

 

 

0322

Port 12: Number of 1023 to maximum

0 to

1

F9

0

 

byte frames received/sent

4294967295

 

 

 

 

 

 

 

 

 

0324

Port 12: Number of MAC error packets

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

0326

Port 12: Number of dropped received

0 to

1

F9

0

 

packets

4294967295

 

 

 

 

 

 

 

 

 

0328

Port 12: Number of multicast frames

0 to

1

F9

0

 

sent

4294967295

 

 

 

 

 

 

 

 

 

032A

Port 12: Number of broadcast frames

0 to

1

F9

0

 

sent

4294967295

 

 

 

 

 

 

 

 

 

032C

Port 12: Number of <64 byte fragments

0 to

1

F9

0

 

with good CRC

4294967295

 

 

 

 

 

 

 

 

 

032E

Port 13: Number of bytes received

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

0330

Port 13: Number of bytes sent

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

0332

Port 13: Number of frames received

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

0334

Port 13: Number of frames sent

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

0336

Port 13: Total bytes received

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

0338

Port 13: Total frames received

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

033A

Port 13: Number of broadcast frames

0 to

1

F9

0

 

received

4294967295

 

 

 

 

 

 

 

 

 

033C

Port 13: Number of multicast frames

0 to

1

F9

0

 

received

4294967295

 

 

 

 

 

 

 

 

 

033E

Port 13: Number of frames with CRC

0 to

1

F9

0

 

error

4294967295

 

 

 

 

 

 

 

 

 

0340

Port 13: Number of oversized frames

0 to

1

F9

0

 

received

4294967295

 

 

 

 

 

 

 

 

 

0342

Port 13: Number of bad fragments

0 to

1

F9

0

 

received (<64 bytes)

4294967295

 

 

 

 

 

 

 

 

 

0344

Port 13: Number of jabber frames

0 to

1

F9

0

 

received

4294967295

 

 

 

 

 

 

 

 

 

0346

Port 13: Number of collisions occurred

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

0348

Port 13: Number of late collisions

0 to

1

F9

0

 

occurred

4294967295

 

 

 

 

 

 

 

 

 

034A

Port 13: Number of 64-byte frames

0 to

1

F9

0

 

received/sent

4294967295

 

 

 

 

 

 

 

 

 

034C

Port 13: Number of 65 to 127 byte

0 to

1

F9

0

 

frames received/sent

4294967295

 

 

 

 

 

 

 

 

 

034E

Port 13: Number of 128 to 255 byte

0 to

1

F9

0

 

frames received/sent

4294967295

 

 

 

 

 

 

 

 

 

0350

Port 13: Number of 256 to 511 byte

0 to

1

F9

0

 

frames received/sent

4294967295

 

 

 

 

 

 

 

 

 

0352

Port 13: Number of 512 to 1023 byte

0 to

1

F9

0

 

frames received/sent

4294967295

 

 

 

 

 

 

 

 

 

0354

Port 13: Number of 1023 to maximum

0 to

1

F9

0

 

byte frames received/sent

4294967295

 

 

 

 

 

 

 

 

 

0356

Port 13: Number of MAC error packets

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

18–18

MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL