INTERNAL DC DUAL-SOURCE POWER INPUT OPTION

CHAPTER C: INTERNAL DC DUAL-SOURCE POWER INPUT OPTION

C.3 Dual-Source Option Theory of Operation

The Dual-Source DC power option is designed using diodes inside of the chassis on each DC power input line. A diode is placed in each of the four input lines (behind the four external power connection terminals) so that power from an external source can only flow into the unit. This allows the unit to operate whenever DC power is correctly applied to either or both of the two inputs.

C–4

MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL

Page 342
Image 342