CHAPTER 3: INSTALLATION

INSTALLATION

Module Model#

Gigabit

 

 

Gb Modules, fixed ports--SFP

 

 

H1 - H6 Module

2 SFP

 

 

H7 Module

2 CU

 

 

H8 - HD Module

1SFP, 1CU

 

 

HE - HJ Module

1 SFP

 

 

HK Module

1 CU

 

 

3.2.0.7Connecting Fiber Optic Cable to SFP Transceivers

1.Before connecting the fiber optic cable, remove the protective dust caps from the tips of the connectors on the PM. Save these dust caps for future use.

2.Wipe clean the ends of the dual connectors with a soft cloth or lint-free lens tissue dampened in alcohol. Make certain the connectors are clean before connecting.

One strand of the duplex fiber optic cable is coded using color bands at regular intervals; you must use the color-coded strand on the associated ports at each end of the fiber optic segment.

3.Find the Transmit (TX) and Receive (RX) markings on the SFP transceiver to verify the top side of it. Some of the transceiver marks arrow sign for up.

4.Position the SFP transceiver correctly before insertion, and then insert the SFP transceiver carefully, until the transceiver connector snap into the place in the socket connector.

5.Connect the Transmit (TX) port on the Multilink PM to the Receive (RX) port of the remote device. Connect the Receive (RX) port on the PM to the Transmit (TX) port of the remote device.

The LINK LED on the front of the PM will illuminate and turn Green, when a proper connection has been established at both ends (and when power is ON in the unit). If LINK is not lit or OFF after cable connection, the normal cause is improper cable polarity. Swap the fiber cables at the PM connector and also check the connectivity on the target device to remedy this situation.

Reconfigure or reboot both the device if required.

If connected properly, you can check via software for verification of the validity of SFP

Gigabit ports.

Make sure Version 3.3 or higher firmware is loaded on the ML1200 switches to support the

SFP transceivers.