GE ML1200 instruction manual Modbus memory map Sheet 4

Models: ML1200

1 344
Download 344 pages 51.98 Kb
Page 297
Image 297

CHAPTER 18: MODBUS PROTOCOL

MODBUS PROTOCOL

Table 18–1: Modbus memory map (Sheet 4 of 33)

Address

Description

Range

Step

Format

Default

 

 

 

 

 

 

00BE

Port 9 activity

0 to 1

1

F3

0

 

 

 

 

 

 

00BF

Port 10 activity

0 to 1

1

F3

0

 

 

 

 

 

 

00C0

Port 11 activity

0 to 1

1

F3

0

 

 

 

 

 

 

00C1

Port 12 activity

0 to 1

1

F3

0

 

 

 

 

 

 

00C2

Port 13 activity

0 to 1

1

F3

0

 

 

 

 

 

 

00C3

Port 14 activity

0 to 1

1

F3

0

 

 

 

 

 

 

00C4

Port 15 activity

0 to 1

1

F3

0

 

 

 

 

 

 

00C5

Port 16 activity

0 to 1

1

F3

0

 

 

 

 

 

 

00C6

Port 17 activity

0 to 1

1

F3

0

 

 

 

 

 

 

00C7

Port 18 activity

0 to 1

1

F3

0

 

 

 

 

 

 

00C8

Port 19 activity

0 to 1

1

F3

0

 

 

 

 

 

 

00C9

Port 20 activity

0 to 1

1

F3

0

 

 

 

 

 

 

00CA

Port 21 activity

0 to 1

1

F3

0

 

 

 

 

 

 

00CB

Port 22 activity

0 to 1

1

F3

0

 

 

 

 

 

 

00CC

Port 23 activity

0 to 1

1

F3

0

 

 

 

 

 

 

00CD

Port 24 activity

0 to 1

1

F3

0

 

 

 

 

 

 

00CE

Port 25 activity

0 to 1

1

F3

0

 

 

 

 

 

 

00CF

Port 26 activity

0 to 1

1

F3

0

 

 

 

 

 

 

00D0

Port 27 activity

0 to 1

1

F3

0

 

 

 

 

 

 

00D1

Port 28 activity

0 to 1

1

F3

0

 

 

 

 

 

 

00D2

Port 29 activity

0 to 1

1

F3

0

 

 

 

 

 

 

00D3

Port 30 activity

0 to 1

1

F3

0

 

 

 

 

 

 

00D4

Port 31 activity

0 to 1

1

F3

0

 

 

 

 

 

 

00D5

Port 32 activity

0 to 1

1

F3

0

 

 

 

 

 

 

00D6

Port 1: Number of bytes received

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

00D8

Port 1: Number of bytes sent

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

00DA

Port 1: Number of frames received

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

00DC

Port 1: Number of frames sent

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

00DE

Port 1: Total bytes received

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

00E0

Port 1: Total frames received

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

00E2

Port 1: Number of broadcast frames

0 to

1

F9

0

 

received

4294967295

 

 

 

 

 

 

 

 

 

00E4

Port 1: Number of multicast frames

0 to

1

F9

0

 

received

4294967295

 

 

 

 

 

 

 

 

 

00E6

Port 1: Number of frames with CRC

0 to

1

F9

0

 

error

4294967295

 

 

 

 

 

 

 

 

 

00E8

Port 1: Number of oversized frames

0 to

1

F9

0

 

received

4294967295

 

 

 

 

 

 

 

 

 

00EA

Port 1: Number of bad fragments

0 to

1

F9

0

 

received (<64 bytes)

4294967295

 

 

 

 

 

 

 

 

 

00EC

Port 1: Number of jabber frames

0 to

1

F9

0

 

received

4294967295

 

 

 

 

 

 

 

 

 

00EE

Port 1: Number of collisions occurred

0 to

1

F9

0

 

 

4294967295

 

 

 

 

 

 

 

 

 

MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL

18–7

Page 297
Image 297
GE ML1200 instruction manual Modbus memory map Sheet 4