ML1200(auth)## reauth port=1 status=enable period=300

Successfully set re-authentication parameter(s)

ML1200(auth)## shoW-port reauth

Port Reauth Status Reauth Period (sec.)

=========================================

1

Enabled

300

2

Enabled

3600

3

Enabled

3600

4

Enabled

3600

5

Enabled

3600

6

Enabled

3600

ML1200(auth)## show-stats port=3

Port 3 Authentication Counters

 

authEntersConnecting

: 3

authEapLogoffsWhileConnecting

: 0

authEntersAuthenticating

: 3

authAuthSuccessesWhileAuthenticating

: 2

authAuthTimeoutsWhileAuthenticating

: 0

authAuthFailWhileAuthenticating

: 0

authAuthReauthsWhileAuthenticating

: 0

authAuthEapStartsWhileAuthenticating

: 1

authAuthEapLogoffWhileAuthenticating

: 0

authAuthReauthsWhileAuthenticated

: 0

authAuthEapStartsWhileAuthenticated

: 0

authAuthEapLogoffWhileAuthenticated

: 0

backendResponses

: 5

backendAccessChallenges

: 2

backendOtherRequestsToSupplicant

: 0

backendNonNakResponsesFromSupplicant

: 2

backendAuthSuccesses

: 2

backendAuthFails

: 0

ML1200(auth)## trigger-reauth port=3

Successfully triggered re-authentication

ML1200(auth)##