Bi-Tronics Submenu

 

Bi-Tronics Submenu

 

 

Note

The Bi-Tronics parameters in the printer must be set the same as the

 

interface in the host computer (at the other end of the data cable of the

 

printer). Otherwise, the printer might not work online, and data characters

 

from the computer might not print or might print as “garbled” text.

 

 

Bi-Tronics

(from page 110)

Prime Signal

Disable*

Enable

TOF Action

Reset*

Do Nothing

* = Factory Default

Buffer Size in

K

1* (1-16)

Prime Signal

Disable. The parallel port does not perform a warm start (reboot) if the host asserts the prime signal.

Enable. The parallel port performs a warm start (reboot) if the host asserts the prime signal.

TOF Action

Reset. A form feed is performed before a warm start when the prime signal is asserted from the host. This setting is used only if the Prime Signal parameter is enabled.

Do Nothing. No form feed is performed on reset.

Buffer Size in K

This option configures the amount of memory allocated for the Bi-Tronics port buffer. You can designate the size of the printer buffer from 1 through 16 Kbytes.