Initializing the Access Server

Using the DIAGNOSE Option with INITIALIZE

Using the DIAGNOSE option with INITIALIZE enables you to test the access server hardware. You can specify three types of tests as described in the INITIALIZE DIAGNOSE Option Tests.

The following example shows the DIAGNOSE option with INITIALIZE:

Local> INITIALIZE DIAGNOSE FULL

This command initializes the access server in the default mode and performs an extended test.

INITIALIZE DIAGNOSE Option Tests

The following table shows the tests that are available as part of the INITIALIZE DIAGNOSE option:

Test

Performs

 

 

Brief

Internal self-test only.

Full

Extended test including in-depth memory test.

Normal (Default)

Standard self-test.

 

 

Specifying the DISABLE OPTION with INITIALIZE

Using the DISABLE option with INITIALIZE loads the software image, but disables the use of the CONNECT command and the AUTOCONNECT function. The following command shows how to use this option:

Local> INITIALIZE DISABLE