Chapter 5---Troubleshooting

Table 5-1Error Codes for the Model 330, 340SC and 370SC Projectors

LED

On-Screen Text

Description

Codes shown along with operator messages.

b

A RAM BATTERY

Memory problem—data may be lost if

 

IS LOW

power-off.

c

COLOR IS

Adjustment being attempted on cut-off gun.

 

CUTOFF

 

d

DSP INIT FAILURE

Convergence logic is dead at power-on.

l

LAMP TO-ON,

Arc lamp did not light.

 

BUT OFF

 

m

LAMP TO -OFF,

Problem detecting arc lamp state.

 

BUT ON

 

p

POWER TO-ON,

Power supply problem.

 

BUT OFF

 

w

POWER TO-OFF,

Power supply problem.

 

BUT ON

 

 

 

 

LED

 

Description

Codes indicating temporary error state or hardware problem.

a

An internal table controlling timing is momentarily full.

e

A CPU trap error has occurred. This is potentially serious.

 

 

f

The internal system command queue is momentarily full.

 

 

g

Problem with the terminal-in port timing.

 

 

h

Problem with the terminal-in port operation.

 

 

i

Problem with the DSP output circuits—convergence may be lost.

 

 

j

DSP time-out—should recover automatically. May affect

 

convergence.

 

 

k

Problem with the IIC hardware—Type 1.

 

 

o

Problem with the IIC hardware—Type 2.

 

 

q

Hardware detected source change but nothing found by software.

 

 

r

Problem with DAC hardware.

 

 

s

Vertical sync not detected.

 

 

t

Loss of video-OK detected.

 

 

u

Problem with Extron communication.

vExtron communication time-out.

Model 330, 340SC, and 370SC Service Manual

5-2

Page 142
Image 142
JVC 370 SC, 330, 340 SC service manual On-Screen Text Description