Chapter 3---Service Adjustments
3.11 Arc Lamp Alignment and Focus
The Arc Lamp must be realigned and refocused whenever the lamp is replaced or becomes defocused or misaligned from physical shock to the projector. Refocusing only may be required if the Arc Lamp has been in use for a long time. Adjustment procedures for Model 330 projectors differ from those for the Model 340SC and Model 370SC projectors and are each detailed in the following sections.
Model 330 Arc Lamp Alignment and Focus
To check Model 330 Arc Lamp alignment, confirm the "hot spot" (brightest area) of the screen is centered on a flat field test pattern.
If the hot spot is not centered, the Arc Lamp needs alignment.
To check if focusing is needed, use a flat field test pattern to measure the brightness at the center of the screen and at the corners with a light meter, using all four (4) corners to determine the
CAUTION! In the interest of safety, please read
these entire procedures, prior to performing any adjustments, in order to become familiar with the special NOTES and CAUTIONS indicated.
To align the Model 330 Arc Lamp (refer to Photo
1.Use a
CAUTION! Be careful to not touch the Arc
2.Insert 2 Allen wrenches in the X and Y adjustment screws.
3.Turn the Allen wrenches in or out to center the hot spot on the screen.
Model 330, 340SC, 370SC Service Manual |