3.11 Arc Lamp Alignment and Focus

Chapter 3---Service Adjustments

3.11 Arc Lamp Alignment and Focus

The Arc Lamp must be realigned and refocused whenever the lamp is replaced or becomes defocused or misaligned from physical shock to the projector. Refocusing only may be required if the Arc Lamp has been in use for a long time. Adjustment procedures for Model 330 projectors differ from those for the Model 340SC and Model 370SC projectors and are each detailed in the following sections.

Model 330 Arc Lamp Alignment and Focus

To check Model 330 Arc Lamp alignment, confirm the "hot spot" (brightest area) of the screen is centered on a flat field test pattern.

If the hot spot is not centered, the Arc Lamp needs alignment.

To check if focusing is needed, use a flat field test pattern to measure the brightness at the center of the screen and at the corners with a light meter, using all four (4) corners to determine the roll-off. The roll-off (gradual decrease in brightness from center to corners) should be between 2:1 and 4:1. Do not try to compensate for a dim corner by adjusting the Arc Lamp—dimness in one or two corners is usually caused by variations in the ILA® assemblies and will be corrected by Shading adjustments. Perform the Arc Lamp focusing procedure only if the roll-off in all four (4) corners is too high.

Model 330 Arc Lamp Alignment and FocusManual background CAUTION! In the interest of safety, please read

these entire procedures, prior to performing any adjustments, in order to become familiar with the special NOTES and CAUTIONS indicated.

To align the Model 330 Arc Lamp (refer to Photo 3-2):

1.Use a long-handled Hexhead tool (a long handle helps keep fingers away from Ignitor terminals) to loosen the four (4) Arc Lamp holding screws very slightly, just so that the washers under the screwheads become loose enough to move on the shaft.

Manual backgroundManual background CAUTION! Be careful to not touch the Arc Lamp—it is very hot! Be especially careful when loosening the bottom screw so that the shaft of the Hex tool does not touch the Ignitor terminals to the right of the tool.

2.Insert 2 Allen wrenches in the X and Y adjustment screws.

3.Turn the Allen wrenches in or out to center the hot spot on the screen.

3-18