Chapter 2—Functional Descriptions

method as the /CORSTRT signal but has a separate command from the SCB. It controls the timing of the top and bottom pincushion correction, top and bottom keystone correction, and horizontal linearity correction. The signal timing is selected by the user and controlled by the SCB. Adjusting PINCUSHION POSN under the TIMING SETUP MENU controls it.

Vertical phase adjustment is accomplished by timing the /VFBST (vertical start) signal with respect to the regenerated vertical sync signal. This signal is generated by counting a commanded number of horizontal lines after the vertical sync signal /VSYNCSC. The signal timing is selected by the user and controlled by the SCB. It is controlled by adjusting PHASE using the up/down arrows.

DC restore timing determines the point in time that the signal is clamped and the DC restore (Section 2.6.4, Video Processor Board) function is accomplished. The user has three (3) choices from which the DC restore timing can be selected. These are Backporch (BP), Tri-level (TL), and Sync-tip (ST). The choices are selected in the SL column of the CHANNEL LIST under the CHANNEL MENU (Figure 5-1, Menu Structure).

The DC restore timing counts a preset number of Hx224 clock pulses after the HSYNC signal leading edge. ST will clamp and DC restore during the time that the HSYNC pulse is active. ST clamping is timed with respect to the leading edge of the HSYNC pulse. It is seldom used but is necessary when there is no back porch to clamp on (image starts immediately after the sync pulse). BP will clamp and DC restore shortly after the HSYNC pulse. BP clamping is timed with respect to the trailing edge of the HSYNC pulse. The timing is calculated to be on the back porch of the signal (after the sync pulse but before the image begins). This is the most frequently used clamp timing.

The default setting for the DC restore timing is BP when a new channel is set up. TL clamping occurs significantly after the HSYNC pulse. The purpose of TL timing is to provide DC restore timing that is compatible with the Tri-level type sync used with HDTV signals. Like BP, TL clamping is timed with respect to the trailing edge of the HSYNC pulse. The output of the Synctip/Backporch circuit is a pulse signal (DCRSTR) going to the VPB.

Serial Communication

The RTG uses only the IIC bus for serial communication with the SCB (Section 2.6.6). The information transferred over the IIC bus is indicated below (I = input to RTG, O = output from RTG). A change in output data generates an interrupt pulse.

Table 2-4IIC BUS Information

I/O

Information

Description

 

 

 

I

Priority Select

Commanded sync selection priority

 

 

(always fixed as described above).

 

 

 

I

Vertical Flyback Start Delay

Commanded V phase.

I

Map Start Delay

Commanded timing for vertical positioning

 

 

of correction map.

I

L Blank

Commanded position of left blanking.

I

R Blank

Commanded position of right blanking.

2-22

Model 330. 340SC, and 370SC Service Manual

Page 34
Image 34
JVC 370 SC, 330, 340 SC service manual Serial Communication, Information Description